SK 3201300 24V DC thermoelectric cooler is designed for PLC control cabinets, machine automation systems and OEM equipment requiring compact DC-powered cooling and heating.
Item No :
SK 3201200Version :
wall-mountedMaterial :
Device: Aluminum, anodizedOrder(MOQ) :
1 pc(s).Color :
Cover: RAL 7015Weight :
4.05 kgETIM 8 :
EC000855ETIM 9 :
EC000855
The SK 3201300 thermoelectric cooling unit is designed for direct integration into 24V DC powered automation equipment, machine control systems and OEM applications. The unit uses Peltier thermoelectric technology to provide cooling and heating functions without compressors or refrigerants. With its solid-state design, the SK 3201300 offers quiet operation, low maintenance requirements and stable temperature control for automation systems operating in demanding environments.
| Article no.: | SK 3201300 |
| Dimensions | Width: 125 mm Height: 400 mm Depth: 155 mm ( Width: 4.92 ˝ Height: 15.7 ˝ Depth: 6.1 ˝ ) |
| Material | Device: Aluminum, anodized |
| General color | RAL 7015 |
| Color | Cover: RAL 7015 |
| Total cooling output to DIN EN 14511 | Cooling output L35 L35/50 Hz: 80 W ( Cooling output L35 L35/50 Hz: 273 BTU/h ) |
| Total cooling output L35 L30 | Cooling output L35 L30/50 Hz : 100 W |
| Rated operating voltage | 24 V (DC) |
| Rated current max. | 4.5 A |
| Start-up current | 4.5 A |
| Air throughput (unimpeded air flow) | External circuit: 45 m³/h Internal circuit: 45 m³/h ( External circuit: 26.5 cfm Internal circuit: 26.5 cfm ) |
| Energy efficiency ratio (EER) 50/60 Hz L35 L35 | Refrigeration factor L35 L35 (EER) 50 Hz: 0.9 |
| Thermal output | 80 W ( 273 BTU/h ) |
| Version | wall-mounted |
| Protection category IP to EN 60 529 |
|
| Type of connection (electrical) | Plug-in Spring Connection Terminal |
| Temperature control | PID control (factory setting: cooling +35 °C / heating +5 °C) |
| Operating temperature range | -30 °C...55 °C ( -22 °F...131 °F ) |
| Setting range – cooling | 5 °C...55 °C |
| Setting range – heating | -10 °C...20 °C |
| Pre-fuse | Miniature circuit-breaker/fuse: 10 A |
| Packaging unit | 1 pc(s). |
| Net weight | 3.249 kg |
| Gross weight | 3.449 kg |
| Customs tariff number | 84186900 |
| EAN | 4028177598621 |
| ETIM 9 | EC000855 |
| ETIM 8 | EC000855 |
| ECLASS 8.0 | 27180704 |
View all Thermoelectric Cooler models, specifications and available options.
Scope of Supply
Each thermoelectric cooler is supplied with all necessary components for installation and operation:
• Thermoelectric cooling and heating unit
• Ready-to-connect wiring with plug-in terminal strip
• Mounting accessories
• Filter mat
• USB A/B interface cable
• Drilling template for installation preparation
Applications
The SK 3201300 thermoelectric cooler is suitable for:
Machine Control Cabinets
Protect PLCs, servo controllers and industrial electronics installed inside automated machinery.
OEM Automation Equipment
Provides compact temperature control for machines where a standard AC cooling solution is not preferred.
24V DC Control Systems
Suitable for equipment using centralized DC power supplies and industrial control architectures.
Precision Industrial Equipment
Helps maintain stable operating conditions for sensitive electronic components.
Before selecting a thermoelectric cooler, consider:
For 24V DC automation systems, the SK 3201300 provides a convenient cooling solution without requiring an additional AC power connection.
Before selecting a model, confirm that the available power supply matches the cooler voltage requirement.
Accessories
The accessories include filter mats, mounting accessories, transportation components and other components for installation and operation of the cooling units.

3201050 Chopped fiber filter mat
Version: for thermoelectric coolers
Suitable for Model: No.3201.200/3201.300
Packaging unit :5 pc(s).
More Details

Length: 5m
Diameter: 6mm
Packaging unit: 5 pc(s).

Packaging unit: 1 pc(s).
Compatible accessories are available for SK 3201300 thermoelectric coolers, including filter mats, condensate hoses and mounting components.
For accessory selection and availability, please contact us.
FAQ
Q1: How do I know if the SK 3201300 is suitable for my electrical enclosure?
A: The suitable model depends on several factors, including enclosure size, internal heat load, ambient temperature and the required temperature difference. The SK 3201300 is designed for applications where electronic components need additional cooling protection beyond natural ventilation. Please provide your cabinet specifications and operating conditions for proper model selection.
Q2: What happens if my electrical cabinet becomes too hot?
A: Excessive heat inside an electrical cabinet can reduce the service life of electronic components and may cause unexpected equipment downtime. The SK 3201300 helps remove additional heat from the enclosure and creates a more suitable operating environment for control components.
Q3: Can the SK 3201300 be used in dusty industrial environments?
A: The SK 3201300 is designed for industrial enclosure applications where electronic components require protection from temperature fluctuations. The actual suitability depends on the installation environment, enclosure protection level and maintenance conditions.
Q4: Will condensation occur when using a thermoelectric cooler?
A: Condensation depends on the temperature difference between the enclosure surface and the surrounding air. Proper temperature settings and installation conditions help reduce condensation risks. Additional accessories, such as condensate management components, can also be used when required.
Q5: Can the SK 3201300 operate continuously?
A: The SK 3201300 is designed for continuous industrial operation. Its solid-state thermoelectric technology has no compressor or moving mechanical parts, reducing wear and improving long-term reliability.