Complete VX25 enclosure system with frame, front door, rear panel, mounting plate, roof plate and divided gland plates, designed for efficient industrial control cabinet installation.
Item No :
VX 8865000Material :
Sheet steelColor :
RAL 7035IK code :
IK10
VX 8865000 is a single-door VX25 bayed enclosure measuring 800 x 1600 x 500 mm. The sheet-steel enclosure includes a mounting plate, rear panel, roof plate and divided gland plates. Its 25 mm pitch pattern and two mounting levels support flexible installation of electrical components, control equipment and cable-management accessories.
The 1600 mm enclosure height is suited to applications that need a lower cabinet while retaining the modular VX25 frame and baying capability. With separately ordered side panels, it can be used as a standalone enclosure or combined with other compatible VX25 enclosures.
We support both single-unit and bulk procurement of VX 8865000, with genuine Rittal products available from stock for fast quotation and delivery.
| Article no.: | VX 8865000 |
| Dimensions | 800 mm x 1600 mm x 500 mm |
| Dimensions mounting plate (W x H) | 699 mm x 1,496 mm |
| Material | Enclosure frame: Sheet steel, 1.5 mm Roof: Sheet steel, 1.5 mm Door: Sheet steel, 2.0 mm Rear panel: Sheet steel, 1.5 mm Gland plates: Sheet steel, 1.5 mm Mounting plate: Sheet steel, 3.0 mm |
| Surface finish | Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated on the outside, textured paint Mounting plate and gland plates: Zinc-plated |
| Colour | RAL 7035 |
| Protection category to IEC 60 529 | IP 55 |
| Protection category NEMA |
|
| Type rating to UL 50E |
|
| IK Code | IK10 |
| Number of doors | 1 |
| Basic material | Sheet steel |
| Packs of | 1 pc(s). |
| Net weight | 99.4 kg |
| Gross weight | 102.4 kg |
| PCF per pack (cradle-to-gate) | 292.25 kg CO2 eq (Cat B) |
| Note on PCF category | Category B: PCF value (cradle-to-gate) based on the product weight, approximately calculated and self-declared |
| Customs tariff number | 94032080 |
| EAN | 4028177813892 |
| ETIM 9 | EC000261 |
| ETIM 8 | EC000261 |
| ECLASS 8.0 | 27180101 |
VX 8865000 may be used as a floor-standing enclosure for machine controls, automation systems, manufacturing equipment and electrical distribution assemblies. It can operate as a standalone cabinet with side panels or as one section of a bayed enclosure suite.
Confirm the following before ordering:
Whether 500 mm depth provides sufficient clearance for equipment, terminals and cable-bending radii
Internal heat losses and the required enclosure climate-control method
Standalone side panels or baying components for an enclosure suite
Required base/plinth height, cable-entry arrangement and transportation accessories
Project-specific protection ratings, approvals and documentation requirements
Common accessory categories for VX 8865000 include:
Accessory compatibility depends on enclosure dimensions, installation position and project configuration. Confirm the required article numbers before placing an order.
View All VX25 Accessories and System Components
Confirm the current certificate edition, language and project acceptance requirements before procurement. Documentation availability may vary by market and document type.
Q1: Is the 1600 mm enclosure height sufficient for my control system?
A: Compare the 699 x 1496 mm mounting plate with the total footprint of the components, wiring ducts and terminals. Also allow space for cable bends, heat separation and future maintenance. If the required layout exceeds this usable area, select a taller VX25 model rather than reducing the recommended installation clearances.
Q2: How can I check whether deep components will fit inside VX 8865000?
A: Measure the complete installed depth of the component, including terminals, connectors, cable-bending space and door-mounted equipment. The mounting plate is depth-adjustable on a 25 mm pitch pattern, but the final position must still provide safe wiring, airflow and service clearance.
Q3: What must be added before VX 8865000 can be used as a standalone enclosure?
A: Side panels are not included and must be ordered separately to close the open sides. Select panels for a 1600 mm high and 500 mm deep VX enclosure. Depending on the installation, the project may also require a base/plinth, cable-entry components, climate-control equipment, earthing accessories and transportation hardware.
Q4: How do I select compatible VX25 accessories for this model?
A: Match side-mounted components to the 1600 mm height and 500 mm depth. Front and rear base/plinth components must match the 800 mm enclosure width, while side trim panels must match the 500 mm depth. Verify the accessory article number, installation position and required quantity before purchase.
Q5: Will cable-entry or cooling cut-outs affect the IP55 protection rating?
A: They can. IP55 applies when the enclosure is correctly assembled with the required side panels. Use compatible cable-entry parts, climate-control equipment, seals and installation methods for every cut-out. Check the protection rating of the completed assembly after all modifications.
Q6: Can VX 8865000 be added to an existing VX25 enclosure line?
A: VX25 enclosures are bayable on all sides, but a 1600 mm high enclosure may not align with taller sections in an existing suite. Confirm enclosure height, depth arrangement, baying connectors, sealing, earthing continuity, base/plinth alignment and cable routing before finalizing the layout.
Q7: Can I purchase VX 8865000 together with the required accessories?
Q: Yes. We support both single-unit and bulk procurement, including model verification, compatible accessory matching, consolidated quotation, technical documentation and international delivery coordination. Confirm current stock and delivery time when requesting a quotation.
Send us the required quantity, delivery country, accessory list and documentation requirements. We can help confirm the model configuration before quotation.
Contact Us About VX 8865000