Complete VX25 enclosure system with frame, front door, rear panel, mounting plate, roof plate and divided gland plates, designed for efficient industrial control cabinet installation.
Item No :
VX 8808000Material :
Sheet steelColor :
RAL 7035IK code :
IK10
VX 8808000 is a single-door VX25 bayed enclosure measuring 800 x 2000 x 800 mm. The sheet-steel enclosure includes a mounting plate, rear panel, roof plate and divided gland plates. Its 25 mm pitch pattern and two mounting levels support flexible installation of electrical components, control equipment and cable-management accessories.
The 800 mm depth provides additional installation and cable-routing space for larger internal assemblies. With separately ordered side panels, it can be installed as a standalone enclosure or bayed with other VX25 enclosures to create a larger enclosure system.
We support both single-unit and bulk procurement of VX 8808000, with genuine Rittal products available from stock for fast quotation and delivery.
| Article no.: | VX 8808000 |
| Dimensions | 800 mm x 2000 mm x 500 mm |
| Dimensions mounting plate (W x H) | 699 mm x 1,896 mm |
| Material | Enclosure frame: Sheet steel, 1.5 mm Roof: Sheet steel, 1.5 mm Door: Sheet steel, 2.0 mm Rear panel: Sheet steel, 1.5 mm Gland plates: Sheet steel, 1.5 mm Mounting plate: Sheet steel, 3.0 mm |
| Surface finish | Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated on the outside, textured paint Mounting plate and gland plates: Zinc-plated |
| Colour | RAL 7035 |
| Protection category to IEC 60 529 | IP 55 |
| Protection category NEMA |
|
| Type rating to UL 50E |
|
| IK Code | IK10 |
| Number of doors | 1 |
| Basic material | Sheet steel |
| Packs of | 1 pc(s). |
| Net weight | 124.14 kg |
| Gross weight | 138.2 kg |
| PCF per pack (cradle-to-gate) | 360.84 kg CO2 eq (Cat B) |
| Note on PCF category | Category B: PCF value (cradle-to-gate) based on the product weight, approximately calculated and self-declared |
| Customs tariff number | 94032080 |
| EAN | 4028177813854 |
| ETIM 9 | EC000261 |
| ETIM 8 | EC000261 |
| ECLASS 8.0 | 27180101 |
VX 8808000 may be used as a floor-standing enclosure for machine controls, automation systems, manufacturing equipment and electrical distribution assemblies. Its 800 mm depth is suitable for configurations requiring additional equipment, cable-routing or thermal-management space.
Confirm the following before ordering:
Required equipment depth, service clearance and cable-bending radii
Internal heat losses and the required enclosure climate-control method
Standalone side panels or baying components for an enclosure suite
Required base/plinth height, cable-entry arrangement and transportation accessories
Project-specific protection ratings, approvals and documentation requirements
Common accessory categories for VX 8808000 include:
Accessory compatibility depends on enclosure dimensions, installation position and project configuration. Confirm the required article numbers before placing an order.
View All VX25 Accessories and System Components
Confirm the current certificate edition, language and project acceptance requirements before procurement. Documentation availability may vary by market and document type.
Q1: Do I need an 800 mm deep enclosure for my project?
A: Choose the 800 mm depth when the installation requires extra room for deep components, cable-bending radii, rear cable routing, cooling equipment or maintenance access. Before ordering, compare the required internal depth with the complete installed depth of the components, wiring ducts, terminals and door-mounted equipment.
Q2: How can I check whether my equipment will fit on the mounting plate?
A: The mounting plate measures 699 x 1896 mm. Check the total component footprint as well as the space required for wiring ducts, terminals, cable bends, ventilation paths and service access. The 800 mm enclosure depth increases front-to-rear installation space, but it does not increase the mounting plate width or height.
Q3: What must be added before VX 8808000 can be used as a standalone enclosure?
A: Side panels are not included and must be ordered separately to close the open sides. Select panels for a 2000 mm high and 800 mm deep VX enclosure. Depending on the installation, the project may also require a base/plinth, cable-entry components, climate-control equipment, earthing accessories and transportation hardware.
Q4: How do I select compatible VX25 accessories for this model?
A: Match side-mounted components to the 2000 mm height and 800 mm depth. Front and rear base/plinth components must match the 800 mm enclosure width, while side trim panels must match the 800 mm depth. Always verify the accessory article number, installation position and required quantity before purchase.
Q5: Will cable-entry or cooling cut-outs affect the IP55 protection rating?
A: They can. IP55 applies when the enclosure is correctly assembled with the required side panels. Use compatible cable-entry parts, climate-control equipment, seals and installation methods for every cut-out. The protection rating of the completed assembly should be checked after all modifications are made.
Q6: Can VX 8808000 be added to an existing VX25 enclosure line?
A: Yes. VX25 enclosures are designed for baying on all sides. Before expanding an existing line, confirm enclosure height, depth arrangement, baying connectors, sealing, earthing continuity, base/plinth alignment and cable-routing requirements.
Can I purchase VX 8808000 together with all required accessories?
Yes. We support both single-unit and bulk procurement, including model verification, compatible accessory matching, consolidated quotation, technical documentation and international delivery coordination. Confirm current stock and delivery time when requesting a quotation.
Send us the required quantity, delivery country, accessory list and documentation requirements. We can help confirm the model configuration before quotation.
Contact Us About VX 8808000