The outlet filter is used in conjunction with the corresponding fan-and-filter unit to dissipate heat loss from enclosures, ventilate the enclosure and protect temperature-sensitive components. This is achieved through the direct infeed of ambient air, the temperature of which must be lower than the permissible internal temperature of the enclosure.
Item No :
SK 3240308Material :
PlasticOrder(MOQ) :
1 pc(s).Color :
RAL 7035Weight :
0.45 kgThe Rittal SK 3240308 is a RAL 9005 black Blue e+ outlet filter for the SK 3240.7xx, 3240.9xx, 3241.7xx and 3241.9xx fan-and-filter families. Installed on an enclosure wall opposite a matching fan, it forms the filtered air outlet. Cooler ambient air enters through the powered fan while heated internal air exits through this grille, helping ventilate equipment inside the enclosure.
| Article no.: | SK 3240308 |
| Product | Blue e+ outlet filter |
| Version | Wall-mounted |
| Dimensions | Width: 255 mm (10.04 in) Height: 255 mm (10.04 in) Depth: 45.2 mm (1.78 in) |
| Mounting cut-out | Width: 224 mm (8.82 in) Height: 224 mm (8.82 in) |
| Suitable for model no. | SK 3240.7xx/3240.9xx/3241.7xx/3241.9xx |
| Benefits | Tool-free mounting Optimized snap hooks for faster enclosure installation Opening louvred grille for easier filter changes |
| Material | Plastic |
| Color | RAL 9005 |
| Supply includes | Outlet filter Pleated filter |
| Protection category NEMA | Type 12 with chopped-fibre filter or pleated filter Type 3, 3R, 4 and 4X with chopped-fibre filter or pleated filter and hose-proof hood |
| IP protection category to IEC 60529 | IP54 with chopped-fibre filter or pleated filter IP55 with pleated filter and absorber mat IP56 with chopped-fibre filter or pleated filter and hose-proof hood |
| Packaging unit | 1 pc(s). |
| Net weight | 0.45 kg |
| Gross weight | 0.665 kg |
| Customs tariff number | 39269097 |
| EAN | 4028177998353 |
| ETIM 9 / ETIM 8 | EC002513 |
| ECLASS 8.0 | 27180706 |
Choose SK 3240308 when the fan belongs to one of the specified Blue e+ SK 3240/3241 families and the outlet grille must be RAL 9005 black. It has a 255 × 255 mm face and fits a 224 × 224 mm mounting cut-out. Check both the grille finish and panel opening before replacing a light-grey version.
The opening louvred grille allows the supplied pleated filter to be reached for inspection and routine changes. Tool-free snap mounting supports installation in the prepared enclosure wall. Filter checks are especially relevant when dust could restrict the ventilation path.
Rittal specifies IP54 and NEMA Type 12 with a pleated filter. Its IP55 arrangement also uses an absorber mat; IP56 and NEMA Type 3/3R/4/4X require a suitable hose-proof hood with the filter. Check the finished enclosure arrangement and select the powered fan according to heat loss and ambient temperature.
| Article number | Use it when | Do not treat as interchangeable when |
|---|---|---|
| SK 3240308 | A matching SK 3240.7xx, 3240.9xx, 3241.7xx or 3241.9xx fan is specified with a RAL 9005 black outlet. | The enclosure design calls for a light-grey grille, an EMC outlet or another cut-out size. |
| SK 3240300 | The matching fan uses the same 224 × 224 mm opening, but the specified outlet finish is RAL 7035 light grey. | The enclosure requires the RAL 9005 black version. |
| SK 3240400 | An SK 3240.8xx or 3241.8xx EMC fan requires its corresponding EMC outlet filter. | The installation calls for a standard SK 3240/3241 Blue e+ fan arrangement. |
| Item | Relevant customer requirement |
|---|---|
| Pleated replacement filter | Inspect the supplied pleated filter as site dust builds up. Confirm a replacement medium sized for the SK 3240/3241 outlet before ordering. |
| SK 3240.080 stainless steel hose-proof hood 282 × 390 × 85 mm |
For the specified IP56 or NEMA Type 3/3R/4/4X arrangement, check the assembled filter-and-hood configuration and leave room for the hood outside the enclosure. |
| Absorber mat | Rittal specifies IP55 when a pleated filter is used with an absorber mat. Confirm the matching accessory and assembly requirements for the installation. |
For model confirmation or quotation, send: the powered fan article number, enclosure heat loss, maximum ambient temperature, permitted internal temperature, required IP/NEMA rating, installation drawing, quantity and delivery destination. These details allow the outlet, airflow and protection arrangement to be checked together.