Complete VX25 enclosure system with frame, front door, rear panel, mounting plate, roof plate and divided gland plates, designed for efficient industrial control cabinet installation.
Item No :
VX 8805000Material :
Sheet steelColor :
RAL 7035IK code :
IK10
VX 8806000 is a single-door VX25 bayed enclosure measuring 800 × 2000 × 600 mm. The 600 mm depth provides more front-to-back installation space than the 500 mm-deep VX 8805000 while retaining the same 800 mm width, 2000 mm height and 699 × 1896 mm mounting plate. This makes VX 8806000 suitable when deeper components, cable ducts, terminals or cable-bending radii require additional clearance without increasing the enclosure width.
The sheet-steel enclosure includes a mounting plate, rear panel, roof plate and divided gland plates. Its symmetrical 25 mm frame pattern supports flexible interior installation, while separately ordered side panels allow standalone use or baying with other VX25 enclosures.
| Article no.: | VX 8806000 |
| Dimensions | 800 mm x 2000 mm x 600 mm |
| Dimensions mounting plate (W x H) | 699 mm x 1,896 mm |
| Material | Enclosure frame: Sheet steel, 1.5 mm Roof: Sheet steel, 1.5 mm Door: Sheet steel, 2.0 mm Rear panel: Sheet steel, 1.5 mm Gland plates: Sheet steel, 1.5 mm Mounting plate: Sheet steel, 3.0 mm |
| Surface finish | Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated on the outside, textured paint Mounting plate and gland plates: Zinc-plated |
| Colour | RAL 7035 |
| Protection category to IEC 60 529 | IP 55 |
| Protection category NEMA |
|
| Type rating to UL 50E |
|
| IK Code | IK10 |
| Number of doors | 1 |
| Basic material | Sheet steel |
| Packs of | 1 pc(s). |
| Net weight | 120.7 kg |
| Gross weight | 125.8 kg |
| PCF per pack (cradle-to-gate) | 352.45 kg CO2 eq (Cat B) |
| Note on PCF category | Category B: PCF value (cradle-to-gate) based on the product weight, approximately calculated and self-declared |
| Customs tariff number | 94032080 |
| EAN | 4028177813847 |
| ETIM 9 | EC000261 |
| ETIM 8 | EC000261 |
| ECLASS 8.0 | 27180101 |
Choose VX 8806000 when a 500 mm-deep enclosure leaves insufficient clearance in front of the mounting plate or between installed components and the door. The additional depth can provide more room for deep control equipment, larger cable ducts, terminal arrangements and routing behind door-mounted equipment.
VX 8806000 is suited to floor-standing machine-control, automation and electrical-distribution layouts that need an 800 mm-wide mounting area with more front-to-back clearance than a 500 mm-deep enclosure. Typical reasons for selecting this model include deeper drives or power components, larger cable ducts, increased terminal clearance and more space for routing conductors between the mounting plate and door area. It can be used as a standalone cabinet with matching side panels or as one section of a bayed VX25 suite.
Confirm the following before ordering:
The deepest installed component, connector projection and clearance to the closed door
Cable-duct depth, terminal access and minimum cable-bending radii
Internal heat losses and the required enclosure climate-control method
Standalone side panels or baying components for an enclosure suite
Required base/plinth height, cable-entry arrangement and transportation accessories
Project-specific protection ratings, approvals and documentation requirements
Common accessory categories for VX 8806000 include:
Accessory compatibility depends on enclosure dimensions, installation position and project configuration. Confirm the required article numbers before placing an order.
View All VX25 Accessories and System Components
Confirm the current certificate edition, language and project acceptance requirements before procurement. Documentation availability may vary by market and document type.
Q1: What are the dimensions of Rittal VX 8806000?
A: VX 8806000 measures 800 mm wide, 2000 mm high and 600 mm deep. It has one front door and a 699 x 1896 mm mounting plate.
Q2: Are side panels included with VX 8806000?
A: No. Side panels are ordered separately. They are required for the open sides when the enclosure is used as a standalone cabinet; bayed installations instead use the applicable connection and sealing components between enclosures.
Q3: What protection ratings apply to VX 8806000?
A: The model is specified as IP55 to IEC 60529 with side panels mounted, NEMA 1 and NEMA 12, Type 1 and Type 12 to UL 50E, and IK10 for impact protection. Final protection depends on correct assembly, cable entry, installed accessories and any enclosure modifications.
Q4: Can VX 8806000 be expanded into a multi-enclosure system?
A: Yes. VX25 enclosures are designed for baying on all sides. Use compatible internal or external baying components and confirm the sealing, grounding, base/plinth and cable-routing requirements for the complete enclosure suite.
Send us the required quantity, delivery country, accessory list and documentation requirements. We can help confirm the model configuration before quotation.
Contact Us About VX 8806000