VX 8884000 VX25 bayed enclosure, 800 × 1800 × 400 mm with mounting plate. View technical specifications, system features, compatible accessories, approvals and documentation.
Item No :
VX 8884000Material :
Sheet steelColor :
RAL 7035IK code :
IK10
VX 8884000 is a single-door VX25 bayed enclosure measuring 800 × 1800 × 400 mm. The sheet-steel enclosure includes a mounting plate, rear panel, roof plate and divided gland plates. Its 400 mm depth provides a relatively shallow floor-standing configuration for industrial control and automation installations where installation depth is limited.
The VX25 modular frame supports flexible internal installation and side-by-side baying with compatible system components. We support single-unit and bulk procurement of VX 8884000, including model verification, accessory matching, consolidated quotations, technical documentation and international delivery coordination.
| Article no.: | VX 8884000 |
| Dimensions | 800 mm x 1800 mm x 400 mm |
| Dimensions mounting plate (W x H) | 699 mm x 1,696mm |
| Material | Enclosure frame: Sheet steel, 1.5 mm Roof: Sheet steel, 1.5 mm Door: Sheet steel, 2.0 mm Rear panel: Sheet steel, 1.5 mm Gland plates: Sheet steel, 1.5 mm Mounting plate: Sheet steel, 3.0 mm |
| Surface finish | Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated on the outside, textured paint Mounting plate and gland plates: Zinc-plated |
| Colour | RAL 7035 |
| Protection category to IEC 60 529 | IP 55 |
| Protection category NEMA |
|
| Type rating to UL 50E |
|
| IK Code | IK10 |
| Number of doors | 1 |
| Basic material | Sheet steel |
| Packs of | 1 pc(s). |
| Net weight | 106.5 kg |
| Gross weight | 109.2 kg |
| PCF per pack (cradle-to-gate) | 311.85 kg CO2 eq (Cat B) |
| Note on PCF category | Category B: PCF value (cradle-to-gate) based on the product weight, approximately calculated and self-declared |
| Customs tariff number | 94032080 |
| EAN | 4028177813922 |
| ETIM 9 | EC000261 |
| ETIM 8 | EC000261 |
| ECLASS 8.0 | 27180101 |
VX 8884000 may be used for machine controls, automation systems, manufacturing equipment and electrical distribution assemblies where a floor-standing enclosure is required but available installation depth is limited.
Its 400 mm depth can help reduce the enclosure footprint compared with deeper VX25 configurations, while the 1800 mm height provides vertical mounting space for control and electrical components. It may be installed as a standalone cabinet with the appropriate side panels or integrated into a bayed VX25 enclosure system.
Confirm the following before ordering:
• Whether 400 mm depth provides sufficient clearance for installed components, terminals and cable-bending radii
• Whether rear wiring, cable ducts and connector clearances can be accommodated within the planned internal layout
• Whether the 1800 mm enclosure height provides sufficient vertical mounting capacity for the equipment
• Internal heat losses and whether the available enclosure depth affects the planned climate-control arrangement
• Standalone side panels or baying components for a multi-enclosure system
• Required base/plinth height, cable-entry arrangement and transportation accessories
• Project-specific protection ratings, approvals and documentation requirements
Common accessory categories for VX 8884000 include:
Accessory compatibility depends on enclosure dimensions, installation position and project configuration. Confirm the required article numbers before placing an order.
View All VX25 Accessories and System Components
Confirm the current certificate edition, language and project acceptance requirements before procurement. Documentation availability may vary by market and document type.
Q1: Is VX 8884000 suitable for installations with limited cabinet depth?
A: The 400 mm depth can be useful where installation depth is limited. Before selection, check the depth of mounted components, terminals, cable ducts, connectors and required cable-bending space to ensure the planned internal layout will fit.
Q2: What should I check before choosing VX 8884000 instead of a deeper VX25 enclosure?
A: Consider component depth, rear wiring clearance, cable routing, connector access and climate-control requirements. A shallower enclosure can reduce the installation footprint, but applications with deeper equipment or extensive cabling may require a deeper VX25 model.
Q3: Can VX 8884000 be used as a standalone cabinet?
A: Yes. For standalone installation, the enclosure must be completed with the appropriate side panels and any other components required for the application. Sealing, cable entry, grounding and the required protection level should also be confirmed before installation.
Q4: How should I select accessories for VX 8884000?
A: Select accessories according to the enclosure dimensions, installation position and intended function. Side panels and other size-dependent components must match the enclosure dimensions, while mounting, baying, cable-entry and door accessories should be verified by article number before ordering.
Send us the required quantity, delivery country, accessory list and documentation requirements. We can help confirm the model configuration before quotation.
Contact Us About VX 8884000