VX 8885000 VX25 bayed enclosure, 800 × 1800 × 500 mm with mounting plate. View technical specifications, system features, compatible accessories, approvals and documentation.
Item No :
VX 8885000Material :
Sheet steelColor :
RAL 7035IK code :
IK10
VX 8885000 is a single-door VX25 bayed enclosure measuring 800 × 1800 × 500 mm. The sheet-steel enclosure includes a mounting plate, rear panel, roof plate and divided gland plates. Its 500 mm depth provides additional installation clearance compared with shallower VX25 configurations while retaining a relatively compact 1800 mm enclosure height.
The VX25 modular frame supports flexible internal installation and side-by-side baying with compatible system components. We support single-unit and bulk procurement of VX 8885000, including model verification, accessory matching, consolidated quotations, technical documentation and international delivery coordination.
| Article no.: | VX 8885000 |
| Dimensions | 800 mm x 1800 mm x 500 mm |
| Dimensions mounting plate (W x H) | 699 mm x 1,696mm |
| Material | Enclosure frame: Sheet steel, 1.5 mm Roof: Sheet steel, 1.5 mm Door: Sheet steel, 2.0 mm Rear panel: Sheet steel, 1.5 mm Gland plates: Sheet steel, 1.5 mm Mounting plate: Sheet steel, 3.0 mm |
| Surface finish | Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated on the outside, textured paint Mounting plate and gland plates: Zinc-plated |
| Colour | RAL 7035 |
| Protection category to IEC 60 529 | IP 55 |
| Protection category NEMA |
|
| Type rating to UL 50E |
|
| IK Code | IK10 |
| Number of doors | 1 |
| Basic material | Sheet steel |
| Packs of | 1 pc(s). |
| Net weight | 109.662 kg |
| Gross weight | 113 kg |
| PCF per pack (cradle-to-gate) | 319.04 kg CO2 eq (Cat B) |
| Note on PCF category | Category B: PCF value (cradle-to-gate) based on the product weight, approximately calculated and self-declared |
| Customs tariff number | 94032080 |
| EAN | 4028177813939 |
| ETIM 9 | EC000261 |
| ETIM 8 | EC000261 |
| ECLASS 8.0 | 27180101 |
VX 8885000 may be used for machine controls, industrial automation systems, manufacturing equipment and electrical distribution assemblies requiring a floor-standing enclosure with moderate installation depth.
The 500 mm depth provides more internal clearance for components, terminals and cable routing than shallower VX25 configurations while avoiding the footprint of significantly deeper enclosures. The 1800 mm height may also suit installations where vertical clearance is more limited than with 2000 mm or 2200 mm VX25 models.
It may be configured as a standalone enclosure with the appropriate side panels or integrated into a multi-enclosure VX25 baying system.
Confirm the following before ordering:
• Whether 500 mm depth provides sufficient clearance for the installed electrical and control components
• Required rear wiring space, terminal clearance and cable-bending radii
• Whether the 1800 mm enclosure height provides sufficient vertical mounting capacity
• Internal heat losses and the required climate-control arrangement
• Standalone side panels or baying components for a multi-enclosure system
• Required base/plinth height, cable-entry arrangement and transportation accessories
• Project-specific protection ratings, approvals and documentation requirements
Common accessory categories for VX 8885000 include:
Accessory compatibility depends on enclosure dimensions, installation position and project configuration. Confirm the required article numbers before placing an order.
View All VX25 Accessories and System Components
Confirm the current certificate edition, language and project acceptance requirements before procurement. Documentation availability may vary by market and document type.
Q1: Is 500 mm depth enough for a typical control cabinet installation?
A: It depends on the installed equipment and wiring layout. The 500 mm depth can accommodate many control and automation configurations, but component depth alone should not determine the selection. Allow space for terminals, cable ducts, connectors, cable-bending radii and access for installation and maintenance.
Q2: Should I choose VX 8885000 or the shallower VX 8884000?
A: The choice should be based primarily on the required internal installation depth rather than external footprint alone. VX 8884000 can be useful where cabinet depth is tightly constrained, while VX 8885000 provides an additional 100 mm of depth for equipment clearance and cable routing. Check the complete internal layout before deciding.
Q3: Can VX 8885000 be used as a standalone enclosure?
A: Yes. For standalone installation, appropriate side panels and any other configuration-specific components must be added. The completed enclosure should be checked for sealing, cable entry, grounding and the required protection level.
Q4: Can VX 8885000 be incorporated into an existing VX25 bayed system?
A: The VX25 platform is designed for bayed installations. Before adding VX 8885000 to an existing lineup, check the adjacent enclosure dimensions, baying hardware, base/plinth arrangement, cable routing and sealing requirements. Sharing the VX25 platform alone does not mean every configuration can be combined without additional planning.
Send us the required quantity, delivery country, accessory list and documentation requirements. We can help confirm the model configuration before quotation.
Contact Us About VX 8885000